RocketRaid why are you not happy
Rocket Raid why are you throwing exceptions on my machine…. Recently, I purchased as Sans Digital TowerRaid TR5M(-B). It’s worked fine for several months but now it’s started to have some strange issues. I’ve found the device running but with only one disk running in a active mode. The read for some reason when offline.
After reviewing my System logs I see all kinds of errors.
The computer has rebooted from a bugcheck. The bugcheck was: 0x000000d1 (0x0000000000000000, 0x000000000000000b, 0x0000000000000000, 0xfffff88001085ae6). A dump was saved in: C:\Windows\MEMORY.DMP. Report Id: 090611-93296-01.
Not good….
With a little investigation it looks like something is up with my RocketRaid. I run the windows debugger against the MEMORY.DMP and found what appears to be the colapret.
Looking at the stacktrace, it looks like RocketRaid is behaving badly.
nt!KeBugCheckEx
nt!KiBugCheckDispatch+0x69
nt!KiPageFault+0x260
rr62x+0x16ae6 <————
rr62x+0x164d2
rr62x+0x1663b
rr62x+0x15f33
rr62x+0x16019
rr62x+0x13c0a
rr62x+0x133dd
rr62x+0x4f0e
rr62x+0x4a3d
nt!KeSynchronizeExecution+0x3b
SCSIPORT!SpMiniPortTimerDpc+0x4d
FOLLOWUP_IP:
rr62x+16ae6 <———-
fffff880`01146ae6 4c8b10 mov r10,qword ptr [rax]
SYMBOL_STACK_INDEX: 3
SYMBOL_NAME: rr62x+16ae6
FOLLOWUP_NAME: MachineOwner
MODULE_NAME: rr62x
IMAGE_NAME: rr62x.sys
DEBUG_FLR_IMAGE_TIMESTAMP: 4b2f0d94
FAILURE_BUCKET_ID: X64_0xD1_rr62x+16ae6
BUCKET_ID: X64_0xD1_rr62x+16ae6
Followup: MachineOwner
————-
0: kd> lmvm rr62x
start end module name
fffff880`01130000 fffff880`0116d000 rr62x (no symbols)
Loaded symbol image file: rr62x.sys
Image path: \SystemRoot\system32\DRIVERS\rr62x.sys
Image name: rr62x.sys
Timestamp: Sun Dec 20 21:54:28 2009 (4B2F0D94)
CheckSum: 000315DD
ImageSize: 0003D000
Translations: 0000.04b0 0000.04e4 0409.04b0 0409.04e4